ARAB FOOD MACHINERY

About this machine

Autoclaves are used to sterilise packaged products that require high temperatures (+100°C) to eliminate or inactivate pathogenic microorganisms.

Static autoclaves: these are suitable for any format and are used for food packaged in tins, jars and other flexible materials.

Internal diameter: 1.300 m.

Equipment & configuration

FEATURES:

- Internal dimensions of the chamber: 0.817 m x 0.82 m x 0.82 m.

- Steam consumption:

- Pressure: 6 bar.

- Steam consumption per cycle: 450 kg

- Required flow rate: 3200 kg/h.

- Steam inlet diameter (mm): 80 mm.

- Steam/condensate outlet diameter: 40 mm.

- Cold water consumption:

- Pressure: 1.5 bar.

- Cold water consumption per cycle: 11.5 m³.

- Required flow rate: 48 m³/h.

- Cold water inlet diameter (mm): 80 mm.

- Cold water inlet diameter (mm): 80 mm.

- Compressed air consumption:

- Pressure: 6 bar.

- Consumption per cycle: 12 Nm³.

- Required flow rate: 120 Nm³/h.

- Inlet diameter (mm):

- Air inlet diameter: 40 mm.

- Air outlet diameter: 40 mm.

- Process water:

- Storage volume: 850 dm³.

- Make-up water inlet diameter: 50 mm.

- Make-up water pressure: 3 bar

- Outlet diameter: 65 mm.

- Pump flow rate: 300 m³/h.

- Consumption may vary depending on the cycle and the temperature before and after sterilisation.

Confirm included equipment →

Packaging & formats

Send your container type, material, dimensions and required format. Our team will check the documented machine configuration, tooling and change parts against your requirements.

Check my packaging requirements →

Technical data

Internal diameter
1.300 m.
- Internal dimensions of the chamber
0.817 m x 0.82 m x 0.82 m.
- Pressure
6 bar.
- Steam consumption per cycle
450 kg
- Required flow rate
3200 kg/h.
- Steam inlet diameter (mm)
80 mm.
- Steam/condensate outlet diameter
40 mm.
- Pressure
1.5 bar.
- Cold water consumption per cycle
11.5 m³.
- Required flow rate
48 m³/h.
- Cold water inlet diameter (mm)
80 mm.
- Cold water inlet diameter (mm)
80 mm.
- Pressure
6 bar.
- Consumption per cycle
12 Nm³.
- Required flow rate
120 Nm³/h.
- Air inlet diameter
40 mm.
- Air outlet diameter
40 mm.
- Storage volume
850 dm³.
- Make-up water inlet diameter
50 mm.
- Make-up water pressure
3 bar
- Outlet diameter
65 mm.
- Pump flow rate
300 m³/h.
Discuss your technical requirements →

Products & applications

Processes

Indicative applications. Suitability depends on the recipe, container and equipment configuration.

Documentation

Request documentation →

Plan your inspection & delivery

Discuss an inspection and, where possible, a demonstration with our team. Send your delivery destination and site access requirements to request a tailored transport proposal.

Discuss logistics →

Questions about this machine

Can I inspect the machine?

Contact us to confirm the location, availability and inspection arrangements for this specific unit.

Is it suitable for my product?

Share the product, packaging, required capacity and process conditions. Our team will help assess compatibility using the documented configuration.

How do I request pricing and delivery?

Use Request information to prepare an enquiry for this machine without registering. Include your destination and any technical requirements.